Special parameters tab

Parameters for waste treatment

Waste and grid dimensions

Shred waste

The shredding of the waste is activated here. If waste is produced during a separation cut, it is cut up with cut-off cuts.

A grid is placed over the waste. On this grid, the waste is cut into small pieces.

Min waste dimension in X

The minimum waste dimension in the X direction is entered here. If the dimension of the waste is within the entered dimensions, it will be cut.

Min waste dimension in Y

The minimum waste dimension in the Y-direction is entered here. If the dimension of the waste is within the entered dimensions, it will be cut.

Max waste dimension in X

The maximum waste dimension in the X direction is entered here. If the dimension of the waste is within the entered dimensions, it will be cut.

Max waste dimension in Y

The maximum waste dimension in the Y direction is entered here. If the dimension of the waste is within the entered dimensions, it will be cut.

Separation grid in X

The distance between the separation cuts in the X direction during shredding is entered here.

Separation grid in Y

The distance between the separation cuts in the Y direction during shredding is entered here.

Sort waste

At the beginning of the machining

Here you activate that the processing of the waste is sorted at the beginning.

At the end of the machining

Here you activate that the processing of the waste is sorted at the end.

In front of the outer contour

Here you activate that the machining of the waste is sorted before the machining of the outer contour.

Sort waste from right to left

Here you activate that the processing of the waste takes place meandering from right to left.

Set parameters for lugs

Microjoint width

The lug width is entered here.

Outer contour and common cut

Set lug

Here you activate that several microjoints are set on the Common Cuts and the outer contours.

Minimum number of microjoints per part

The minimum number of microjoints per part is entered here.

Common cut

Maximum length without microjoint

The maximum distance from microjoint to microjoint on the separation cut is entered here.

Outer contour

Maximum length without microjoint

The maximum distance from microjoint to microjoint on the outer contour is entered here.

Island

Set lug

Here you activate that several microjoints are set down on the waste.

Minimum number of microjoints per island

The minimum number of microjoints per waste is entered here.

Maximum length without microjoint

The maximum distance from microjoint to microjoint is entered here.