Check sheet length
With the Check sheet length function, the sheet is enlarged in the X direction if the distance between the separation cuts and the edge of the sheet is less than four times the sheet thickness. The sheet is then enlarged until the distance to the sheet edge is at least equal to the minimum shear width.
Check sheet length
- You have opened a sheet of a nesting.
- Under Manufacturer > Manufacturer > Pivatic, click the Check sheet length button.
- A check is made to ensure that the minimum shear width is maintained at the edge of the sheet.
- The sheet is enlarged in the X direction if necessary.